Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Parkinsonism Relat Disord ; 121: 105959, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38246833

RESUMEN

BACKGROUND: Studies have suggested that intrinsic auricular muscle zones (IAMZ) stimulation alleviates motor features of Parkinson disease (PD). METHODS: A randomized, blinded, active sham-controlled pilot trial was conducted to evaluate the safety and dose-response-time curve of Earstim using a 3-treatment, 3-period crossover design in PD patients experiencing OFF time on levodopa. Treatments were: short (20-min) IAMZ stimulation; long (60-min) IAMZ stimulation; and 20-min active sham stimulation of non-muscular areas. Assessment time points were: prior to treatment, and 20, 40, 60, 90, and 120 min after treatment onset. Primary safety endpoints were adverse events frequency and severity. Primary efficacy endpoint was the change in MDS-UPDRS motor score at 20 min after treatment onset in the IAMZ treatment groups versus sham. RESULTS: Forty-six individuals consented; 38 were randomized (average age 64 years, 65 % male, mean 8.2 years from diagnosis). No serious adverse events or significant device-related events occurred. At 20 min after treatment onset, motor improvements did not differ between IAMZ treatments versus sham. However, at 60 min after treatment onset, motor improvement peaked on IAMZ treatments compared to sham (difference: 3.1 [-5.9 to 0.3], p = 0.03). While the difference in 120-min AUC change between IAMZ treatments versus sham was not significant, the short-stimulation IAMZ treatment showed the largest aggregate motor score improvement (AUC = -456 points, 95 % CI -691 to -221) compared to sham. CONCLUSION: Earstim was well-tolerated. The greatest motor improvement occurred at 60 min after stimulation onset in the short-stimulation IAMZ treatment, and supports its further study to alleviate OFF periods.


Asunto(s)
Enfermedad de Parkinson , Femenino , Humanos , Masculino , Persona de Mediana Edad , Antiparkinsonianos/uso terapéutico , Método Doble Ciego , Levodopa/efectos adversos , Músculos , Enfermedad de Parkinson/terapia , Proyectos Piloto , Resultado del Tratamiento , Anciano
2.
Sensors (Basel) ; 22(12)2022 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-35746395

RESUMEN

Parkinson's disease affects millions worldwide with a large rise in expected burden over the coming decades. More easily accessible tools and techniques to diagnose and monitor Parkinson's disease can improve the quality of life of patients. With the advent of new wearable technologies such as smart rings and watches, this is within reach. However, it is unclear what method for these new technologies may provide the best opportunity to capture the patient-specific severity. This study investigates which locations on the hand can be used to capture and monitor maximal movement/tremor severity. Using a Leap Motion device and custom-made software the volume, velocity, acceleration, and frequency of Parkinson's (n = 55, all right-handed, majority right-sided onset) patients' hand locations (25 joints inclusive of all fingers/thumb and the wrist) were captured simultaneously. Distal locations of the right hand, i.e., the ends of fingers and the wrist showed significant trends (p < 0.05) towards having the largest movement velocities and accelerations. The right hand, compared with the left hand, showed significantly greater volumes, velocities, and accelerations (p < 0.01). Supplementary analysis showed that the volumes, acceleration, and velocities had significant correlations (p < 0.001) with clinical MDS-UPDRS scores, indicating the potential suitability of using these metrics for monitoring disease progression. Maximal movements at the distal hand and wrist area indicate that these locations are best suited to capture hand tremor movements and monitor Parkinson's disease.


Asunto(s)
Enfermedad de Parkinson , Temblor , Mano , Humanos , Movimiento , Enfermedad de Parkinson/diagnóstico , Calidad de Vida , Temblor/diagnóstico
3.
Sensors (Basel) ; 22(5)2022 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-35270972

RESUMEN

The Unified Parkinson's Disease Rating Scale (UPDRS) is a subjective Parkinson's Disease (PD) physician scoring/monitoring system. To date, there is no single upper limb wearable/non-contact system that can be used objectively to assess all UPDRS-III motor system subgroups (i.e., tremor (T), rigidity (R), bradykinesia (B), gait and posture (GP), and bulbar anomalies (BA)). We evaluated the use of a non-contact hand motion tracking system for potential extraction of GP information using forearm pronation-supination (P/S) motion parameters (speed, acceleration, and frequency). Twenty-four patients with idiopathic PD participated, and their UPDRS data were recorded bilaterally by physicians. Pearson's correlation, regression analyses, and Monte Carlo validation was conducted for all combinations of UPDRS subgroups versus motion parameters. In the 262,125 regression models that were trained and tested, the models within 1% of the lowest error showed that the frequency of P/S contributes to approximately one third of all models; while speed and acceleration also contribute significantly to the prediction of GP from the left-hand motion of right handed patients. In short, the P/S better indicated GP when performed with the non-dominant hand. There was also a significant negative correlation (with medium to large effect size, range: 0.3-0.58) between the P/S speed and the single BA score for both forearms and combined UPDRS score for the dominant hand. This study highlights the potential use of wearable or non-contact systems for forearm P/S to remotely monitor and predict the GP information in PD.


Asunto(s)
Enfermedad de Parkinson , Marcha , Análisis de la Marcha , Humanos , Enfermedad de Parkinson/diagnóstico , Postura , Pronación , Supinación , Extremidad Superior
4.
Front Neurol ; 11: 546123, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33117256

RESUMEN

It has been demonstrated that intrinsic auricular muscles zone stimulation (IAMZS) can improve the motor symptoms of Parkinson's disease (PD) patients who are examined with the Unified Parkinson's Disease Rating Scale (UPDRS) motor scores. In the present pilot study, using motion capture technology, we aimed to investigate the efficacy of IAMZS compared to medication alone or in combination with medication. Ten PD patients (mean age: 54.8 ± 10.1 years) were enrolled. Each participant participated in three different sessions: sole medication, sole stimulation-20 min of IAMZS, and combined IAMZS (20 min) and medication. Each session was performed on different days but at the same time to be aligned with patients' drug intake. Motion capture recording sessions took place at baseline, 20, 40, and 60 min. Statistical analysis was conducted using one-way repeated measures ANOVA. Bonferroni correction was implemented for pairwise comparisons. The sole medication was ineffective to improve gait-related parameters of stride length, stride velocity, stance, swing, and turning speed. In the sole-stimulation group, pace-related gait parameters were significantly increased at 20 and 40 min. These improvements were observed in stride length at 20 (p = 0.0498) and 40 (p = 0.03) min, and also in the normalized stride velocity at 40 min (p-value = 0.02). Stride velocity also tended to be significant at 20 min (p = 0.06) in the sole-stimulation group. Combined IAMZS and medication demonstrated significant improvements in all the time segments for pace-related gait parameters [stride length: 20 min (p = 0.04), 40 min (p = 0.01), and 60 min (p < 0.01); stride velocity: 20 min (p < 0.01), 40 min (p = 0.01), and 60 min (p < 0.01)]. These findings demonstrated the fast action of the IAMZS on PD motor symptoms. Moreover, following the termination of IAMZS, a prolonged improvement in symptoms was observed at 40 min. The combined use of IAMZS with medication showed the most profound improvements. The IAMZS may be particularly useful during medication off periods and may also postpone the long-term side effects of high-dose levodopa. A large scale multicentric trial is required to validate the results obtained from this pilot study. Clinical Trial Registration: www.ClinicalTrials.gov, identifier NCT03907007.

5.
Front Hum Neurosci ; 11: 338, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28701941

RESUMEN

Background: Deep brain stimulation of the subthalamic nucleus (STN-DBS) and the pedunculopontine nucleus (PPN) significantly improve cardinal motor symptoms and postural instability and gait difficulty, respectively, in Parkinson's disease (PD). Objective and Hypothesis: Intrinsic auricular muscle zones (IAMZs) allow the potential to simultaneously stimulate the C2 spinal nerve, the trigeminal nerve, the facial nerve, and sympathetic and parasympathetic nerves in addition to providing muscle feedback and control areas including the STN, the PPN and mesencephalic locomotor regions. Our aim was to observe the clinical responses to IAMZ stimulation in PD patients. Method: Unilateral stimulation of an IAMZ, which includes muscle fibers for proprioception, the facial nerve, and C2, trigeminal and autonomic nerve fibers, at 130 Hz was performed in a placebo- and sham-controlled, double-blinded, within design, two-armed study of 24 PD patients. Results: The results of the first arm (10 patients) of the present study demonstrated a substantial improvement in Unified Parkinson's Disease Ratings Scale (UPDRS) motor scores due to 10 min of IAMZ electrostimulation (p = 0.0003, power: 0.99) compared to the placebo control (p = 0.130). A moderate to large clinical difference in the improvement in UPDRS motor scores was observed in the IAMZ electrostimulation group. The results of the second arm (14 patients) demonstrated significant improvements with dry needling (p = 0.011) and electrostimulation of the IAMZ (p < 0.001) but not with sham electrostimulation (p = 0.748). In addition, there was a significantly greater improvement in UPDRS motor scores in the IAMZ electrostimulation group compared to the IAMZ dry needling group (p < 0.001) and the sham electrostimulation (p < 0.001) groups. The improvement in UPDRS motor scores of the IAMZ electrostimulation group (ΔUPDRS = 5.29) reached moderate to high clinical significance, which was not the case for the dry needling group (ΔUPDRS = 1.54). In addition, both arms of the study demonstrated bilateral improvements in motor symptoms in response to unilateral IAMZ electrostimulation. Conclusion: The present study is the first demonstration of a potential role of IAMZ electrical stimulation in improving the clinical motor symptoms of PD patients in the short term.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...